| Sign In | Join Free | My autochinanet.com |
|
Brand Name : GENY
Model Number : YCATS II
Certification : ISO, CE
Place of Origin : China
MOQ : 1
Price : negotiate rates
Payment Terms : T/T, L/C, D/P, T/T
Supply Ability : 2 sets/ 3 months
Delivery Time : 6~8weeks
Packaging Details : Plywood cases
Communication Protocol : Modbus RTU, Modbus TCP, DNP3.0
Control Software : Graphical user interface (GUI)
Dimensions : Customizable based on customer's requirements
Test Frequency : 50Hz/60Hz
Accuracy Level : 0.05%, 0.1%, 0.2%
Testing Standards : IEC 62053-21, IEC 62053-22, IEC 62053-23
Power Supply : 220V/110V, 50Hz/60Hz
Application : Energy meter testing
Operating System : Windows
Test Voltage Range : 0-500V
Test Current Range : 0-200A
Function : Automatically test energy meters for accuracy and functionality
This is a 3-phase automatic test line featuring a power cabinet (model: YC1893D) and 20 test stations. Each station is equipped with an Isolated Current Transformer (ICT model: TICT-100) for independent operation. The automated system utilizes pneumatic drive and includes a robotic arm.
Application Conditions and Requirements | |||||
| Environment | Power Requirement | Safety | |||
| Operation Temperature | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
| -10°C--+40ºC | 35%--85% | <2500m | 3x220/380V±10% (or customized) 50/60Hz±2Hz | IP30 | CE conform |
| Type | YCS-103-250 | YCS-103-800 | YCS-103-1200 | YCS-203-2500 |
| Voltage | ||||
| Test voltage output(Phase-Neutral) | 3x(24V-300V)(or customized) | |||
| Power of the voltage output | Max.3x100VA | Max.3x250VA | Max.3x500VA | Max.3x1000VA |
| Resolution | Better than 0.01%of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005%/h(integration time 150 s) | |||
| Load regulation from 0-max.load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd-41st free programmable | |||
| Current | ||||
| Test current output | 3x(1mA-120A/200A) | |||
| Power of the current output | Max.3x250VA | Max.3x500VA | Max.3x1000VA | Max.3x2000VA |
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05%at the final range value | |||
| Stability | Better than 0.005%/h(integration time 150 s) | |||
| Load regulation from 0-max.load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd-41st free programmable | |||
| Phase angle | ||||
| Range | 0-360° | |||
| Resolution | 0.01° | |||
| Setting accuracy | 0.1° | |||
| Frequency | ||||
| Range | 45Hz-65Hz | |||
| Resolution | 0.01Hz | |||
| Error display | ||||
| Type of error display | Red LED | |||
| Resolution of the error displays | 8 digits | |||
*If you want to know more please check our official website:http://www.genymetertestequipment.com/


|
|